Please wait a minute...

大连海洋大学学报  2011, Vol. 26 Issue (1): 27-31    DOI: 10.3969/j.issn.1000-9957.2011.01.006
  |
用化学发光免疫法检测有机氯农药DDTs的残留量
张峰,倪慧,张斯
大连海洋大学生命科学与技术学院,辽宁大连
大连海洋大学辽宁省海洋生物资源恢复与生境修复重点实验室,辽宁大连
Chemiluminescence immunoassay of organochlorine pesticides DDTs residues
ZHANG Feng,NI Hui,ZHANG Si
下载:  HTML  PDF (921KB) 
输出:  BibTeX | EndNote (RIS)      
摘要 建立了检测有机氯农药DDTs残留的化学发光免疫分析技术(chemiluminescence immunoassay,CLIA),以鲁米诺和过氧化氢作为化学发光底物,测定样品中有机氯农药DDTs残留.结果表明:发光底物液非催化下,5~7 min后发光值较稳定;在发光底物液酶催化下,反应10 min接近峰值;DDTs标准曲线线性范围为0.05~25 ng/mL,标准样品DDTs浓度与发光值呈现很好的线性相关,线性方程为y=-63.806x+13426,R2=0.9945,检测最低限为0.05 ng/mL;回收率为91.4%~107.8%.
服务
把本文推荐给朋友
加入引用管理器
E-mail Alert
RSS
作者相关文章
张峰
倪慧
张斯
关键词:  有机氯农药  DDTs残留  化学发光免疫分析    
Abstract: The chemiluminescence immunoassay(CLIA)method,luminol as CLIA substrate and H2O2as oxidant of luminal,was established for detection of organochlorine pesticides DDTs residues.The results showed that luminescence substrate solution had low and constant luminescence values in 5-7 minutes under uncatalyzed condition, and the peak of the luminescence substrate solution was observed in 10 minutes under catalyzed condition and then the luminescence values began to decrease.The standard curve was found to be linear from 0.05 ng/mL to 25 ng/mL,and linear equation was expressed as y=-63.806x+13426,R2=0.9945,with the minimal detection limit of 0.05 ng/mL,and the recovery varying from 91.4%to 107.8%.
Key words:  organochlorine pesticides    DDTs residues    chemiluminescence immunoassay
               出版日期:  2011-02-21      发布日期:  2019-08-30      期的出版日期:  2011-02-21
中图分类号:  TS207.5  
引用本文:    
张峰, 倪慧, 张斯. 用化学发光免疫法检测有机氯农药DDTs的残留量[J]. 大连海洋大学学报, 2011, 26(1): 27-31.
链接本文:  
https://xuebao.dlou.edu.cn/CN/10.3969/j.issn.1000-9957.2011.01.006  或          https://xuebao.dlou.edu.cn/CN/Y2011/V26/I1/27
[1] 萨仁托雅, 张峰, 郑有虎, 卢亚楠. 化学发光免疫分析与酶联免疫分析法检测水产品药物残留的比较研究[J]. 大连海洋大学学报, 2014, 29(5): 486-491.
No Suggested Reading articles found!